Electronics Weekly.com"> The mysterious case of a shocking light switch (Made By Monkeys)

« I can't believe someone makes.... USB construction sites | Main | Impossible objects #10: Wingdings keyboard »

The mysterious case of a shocking light switch

spark generic.jpgStuart Paterson relates a story that happened to him a number of years ago.
"A friend had asked me to have a look at a light switch in her house. Every now and again they got an electric shock when switching on the light. Our mains is 230V so the shock was sometimes quite painful, and I'm sure it was pure luck that no one had been injured. As she rented the property, my friend had contacted her landlord numerous times. In fact,  three different electricians had been out to have a look at the switch. It had been replaced twice.

I removed the switch and checked the wiring, which looked okay. I then checked for continuity between the earth point on the switch and a radiator on the other side of the room. It checked out fine, and as I could see no other fault in such a simple device, I was stumped.
Just then someone walked in the room and a big spark flashed on the radiator where I had terminated the test wire. The wire was lying on top of a metal strip holding the carpets down between the door frame. It was then that the fault dawned on me -- the metal strip  had been screwed down with screws that were far too long. When someone stepped on the metal strip their weight caused it to sag slightly, pushing the screw into what I can only presume was a live cable below. When a person touched one of the metal screws securing the light switch, they completed the circuit and got a shock!

The fix involved simply changing the screws for ones of the correct length."
Karen Field

(This post originally appeared on Made By Monkey's American cousin, on Design News.)

(Picture - Sparks by SadJr, under Creative Coomons Attribution Licence)

TrackBack

TrackBack URL for this entry:
http://www.electronicsweekly.com/cgi-bin/mt/mt-tb.cgi/56183

Comments (3)

There's a discussion on the related issue of plug/wiring safety following the TED talk John La Grou plugs smart power outlets.

br -d

Lawrence Mayes:

If the insulation on a live cable had been damaged then the cable should have been replaced. But who knows what had really happened? If a hidden fault is supected then a proper inspection should be made - it isn't sufficient to mask the symptons of a fault (by changing the screws in this case) and pretending you've done a proper job.

Peter F Vaughan:

So, it wasn't the light switch that was live. It was the carpet strip!

I agree totally with Lawrence above - if the screws had run into the cable, then the cable should have been replaced - or at the very least, the insulation made good by disconnecting one end, running heatshrink over the damaged bits, and reconnecting. Of course, this would only be possible if the cable has a single conductor.

Post a comment

(If you haven't left a comment here before, you may need to be approved by the site owner before your comment will appear. Until then, it won't appear on the entry. Thanks for waiting.)

About

This page contains a single entry from the blog posted on June 26, 2009 4:19 PM.

The previous post in this blog was I can't believe someone makes.... USB construction sites.

The next post in this blog is Impossible objects #10: Wingdings keyboard.

Many more can be found on the main index page or by looking through the archives.

RSS Subscribe to this blog's feed
[What is this?]

Sign up for the fortnightly Made By Monkeys eNewsletter. Get the blog highlights straight to your email inbox, no fuss. Just tick the option for Made By Monkeys.
ElectronicsNews on Twitter Follow ElectronicsNews

Recent Comments

  • Peter F Vaughan on The mysterious case of a shocking light switch: So, it wasn't the light switch that was live. It read more
  • Lawrence Mayes on The mysterious case of a shocking light switch: If the insulation on a live cable had been damaged read more
  • David Mery on The mysterious case of a shocking light switch: There's a discussion on the related issue of plug/wiring safety read more